[OpenBSD]

Manual Page Search Parameters

SAFTE(4) Device Drivers Manual SAFTE(4)

NAME

safteSCSI Accessed Fault-Tolerant Enclosure

SYNOPSIS

safte* at scsibus?

DESCRIPTION

The safte driver provides support for monitoring the various environmental sensors present in SCSI enclosures using the SCSI Accessed Fault-Tolerant Enclosure command set. The hardware monitor is used with the sysctl(8) interface.
SAF-TE compliant devices can provide an arbitrary set of sensors from the following types:
Sensor Units Typical Use
temp uK temperature
fan RPM fan
psu On/Off power supply
doorlock On/Off door lock
alarm On/Off enclosure alarm
Sensor data is updated every 10 seconds.
An enclosure may provide environmental information using an alternative to the SCSI Accessed Fault-Tolerant Enclosure command set used by this driver. Enclosures using the SCSI Enclosure Services command set may be monitored by the ses(4) driver.

SEE ALSO

intro(4), scsibus(4), ses(4), sensorsd(8), sysctl(8)

HISTORY

The safte driver first appeared in OpenBSD 3.8.

AUTHORS

The safte driver was written by David Gwynne <dlg@openbsd.org>.
July 16, 2013 OpenBSD-current